Do you have a Fluke, GE/Druck, Martel, or Transmation calibrator and need an upgrade to PIE?
Use the below cross reference guide to find the recommended PIE replacement.
A Fluke calibrator for process instruments is large with lots of buttons versus the small size and easy to use interface of a PIE Calibrator. The Fluke 725 and Fluke 726 process calibrators require complicated hookups with easily lost jumper wires for RTD connections while the PIE 820 & PIE 830 use true 2, 3 & 4 wire connections. The Fluke 714, Fluke 714B thermocouple calibrators and the Fluke 724 Thermocouple/RTD calibrator require miniature thermocouple connectors to plug in wires while the PIE 422 and PIE 525B accept bare thermocouple wires under screws as well as miniature thermocouple connectors.
Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Fluke process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.
Upgrade to PIE
Type | Fluke Model | PIE Model |
---|---|---|
Multifunction | Fluke 725 | |
Multifunction | Fluke 726 | PIE 830 |
Thermocouple | Fluke 714 | PIE 422 |
RTD | Fluke 712 | PIE 311 |
Thermocouple & RTD | Fluke 724 | PIE 525B |
Milliamp | Fluke 705 | PIE 334 |
Milliamp | Fluke 707 | PIE 434 |
Milliamp | Fluke 709 | PIE 434 |
Milliamp & Voltage | Fluke 715 | PIE 532 |
Thermocouple & mA | Fluke 714B | PIE 422Plus |
RTD & mA | Fluke 712B | PIE 311Plus |
RTD, Thermocouple & mA | Fluke 724 | PIE 525Plus |
A GE Calibrator or Druck Calibrator is complicated versus the small size and easy to use interface of a PIE Calibrator. The DPI 811 and DPI 812 and DPI 880 calibrators require complicated hookups with easily lost jumper wires for RTD connections while the PIE 820 & PIE 830 use true 2, 3 & 4 wire connections. The Druck DPI 821 and Druck 822 thermocouple calibrators require miniature thermocouple connectors to plug in wires while the PIE 422 and PIE 525B accept bare thermocouple wires under screws as well as miniature thermocouple connectors.
Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Fluke process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.
Upgrade to PIE
Type | GE Sensing/Druck Model | PIE Model |
---|---|---|
Multifunction | GE/Druck DPI 880 | PIE 830 |
Thermocouple | GE/Druck DPI 821 or GE/Druck DPI 822 | PIE 422 |
RTD | GE/Druck DPI 811 or GE/Druck DPI 812 | PIE 311 |
Milliamp | GE/Druck UPS II | PIE 334 |
Milliamp | GE/Druck UPS III | PIE 434 |
Milliamp & Voltage | GE/Druck DPI 832 | PIE 532 |
Frequency | GE/Druck DPI 841 or GE/Druck DPI 842 | PIE 541 |
Thermocouple & mA | GE/Druck 822 | PIE 422Plus |
RTD & mA | GE/Druck 812 | PIE 311Plus |
As of 2021 Martel Calibrators are no longer being manufactured. Support is limited as service and replacement parts become harder to find. This includes several models which were labeled under other brand names.
A Martel Calibrator is large with lots of buttons versus the small size and easy to use interface of a PIE Calibrator. The Martel MC-1010 and Martel MC-1210 process calibrators require complicated hookups with easily lost jumper wires for RTD connections while the PIE 820 & PIE 830 use true 2, 3 & 4 wire connections. The Martel PTC-8010 Thermocouple/RTD calibrator require miniature thermocouple connectors to plug in wires while the PIE 525B accept bare thermocouple wires under screws as well as miniature thermocouple connectors.
Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Martel calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.
Upgrade to PIE
Type | Martel Model | PIE Model |
---|---|---|
Multifunction | Martel MC-1210 | |
Multifunction | Martel MC-1010 | PIE 820 |
Multifunction 10-50mA | Martel MC-1210-50 | PIE 850 |
Thermocouple | Martel TC-100 | PIE 422 |
Thermocouple & RTD | Martel PTC-8010 | PIE 525B |
Milliamp | Martel LC-110 | PIE 434 |
Milliamp | Martel LC-100 | PIE 334 |
Milliamp | Martel MS-420 | PIE 334 |
Milliamp & Voltage | Martel PSC-4010 or Martel IVC-222HPII | PIE 532 |
10-50 Milliamp & Voltage | Martel PSC-4010-50 | PIE 535 |
Transmation calibrators have been around since the late 1960s. The first milliamp calibrators had analog meter movements and were housed in extruded aluminum enclosures that were large and heavy. The Transmation 1040 became a standard for instrument technicians even though the digits on the LCD display were the size of a digital watch display. The Transmation 1040, and the Transmation 1080 combined a 4 to 20 milliamp, 10 to 50 milliamp, and voltage calibrator into one device. These were discontinued in 2001.
Other discontinued models include the Transmation 1060, 1061, 1062, 1064P and 1065-MTC thermocouple calibrators, Transmation 1074 and CheckMate 500 RTD calibrators, Transmation 1021, 1022, 1027, 1028, 1030, 1143, 1180 and CheckMate 100 milliamp calibrators, 1188 & CheckMate 100 multifunction calibrator and the Transmation 1070 & 1174 frequency calibrators. Many of these models are so old they that replacement parts no longer exist and are no longer repairable. Or for the models that can be repaired, the cost of repair often exceeds the cost of a replacement PIE calibrator!
When you check the accuracy of some of these obsolete calibrators you will find that they are no longer accurate enough to calibrate modern process instruments. Why risk using a piece of test equipment designed in the 1970s or 1980s to calibrate a state-of-the-art control system.
Transmation calibrators also used miniature banana jacks that required non-standard test leads and many of them contained expensive rechargeable battery packs. PIE Calibrators use standard, replaceable “AA” and 9V batteries and have standard banana jacks and come with standard test leads. Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Transmation process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.
Upgrade to PIE
Type | Transmation Model | PIE Model |
---|---|---|
Multifunction | Transmation CheckMate 1000 | PIE 820 |
Multifunction | Transmation 1188 | PIE 830 |
Thermocouple | Transmation CheckMate 400 | PIE 322-1 |
Thermocouple | Transmation 1064P, 1060, 1061 & 1062 | PIE 322-1 |
Thermocouple | Transmation 1065-MTC | PIE 422 |
RTD | Transmation 1074 | PIE 311 |
RTD | Transmation CheckMate 500 | PIE 311 |
RTD | Transmation 1173 | PIE 311 |
Milliamp | Transmation CheckMate 100, 1021, 1022, 1027, 1028 & 1030 | PIE 334 |
Milliamp | Transmation 1143 | PIE 434 |
Milliamp | Transmation 43 | PIE 434 |
Milliamp (4-20) & Voltage | Transmation 1040, 1045, 1080 or 1180 | PIE 532 |
Milliamp (10-50) & Voltage | Transmation 1048 | PIE 535 |
Milliamp (10-50) & Voltage | Transmation 1040 or 1080 | PIE 535 |
Voltage | Transmation CheckMate 200 | PIE 235 |
Frequency | Transmation 1070, 1173 or CheckMate 300 | PIE 541 |
Discontinued PIE Calibrators and Recommended Replacements
Find the recommended replacement for your discontinued PIE Calibrators. PIE will continue to support these with annual recalibration and repair for as long as parts are still available.
Need More Information?
Practical Instruments consists of a world-class team with 30+ years of experience in design, repair and recalibration services. Give us a call. We would love to work with you.